Line load, angle, material and holder stiffness
| Dryer doctor | Sheet release and wrap prevention; felt side and sheet side run different line loads |
| Calender doctor | Removes build-up on the roll face and lifts fast on a break |
| Coating blade | Meters coat weight; blade form decides cross-direction uniformity |
| Sealing blade | Seals size-press and coating-head chambers against colour migration |
| Blade material | Steel, ceramic, composite β hardness and toughness trade off directly |
| Holder type | Rigid beam with air-tube loading; some machines add micro-adjust screws and quick-change |
| Uneven line load | CD basis weight or coat weight drifts, patchy doctoring; usually air-tube pressure or holder distortion |
| Angle drift | Blade chatter, more dust, regular marking on the roll face |
| Worn or chipped blade | Poor doctoring, coating misses, residue on roll; a chipped ceramic blade also scores the roll |
| Holder distortion | Crown no longer matches, tight at ends and loose in the middle; straightness measurement decides |
| Air-tube leak | Pressure will not hold, slow lift; check both fittings and tube body |
| Loose clamping | Blade creeps, ends wear first; re-torque clamps and fasteners to spec |
| Steel blade | General purpose, tough, low cost; suits moderate line load and standard grades |
| Ceramic blade | High line load, long change interval; brittle, no hammering during fitting, needs a stiff holder |
| Composite blade | Roll-friendly, quieter; suits soft roll covers and high-speed machines |
| Line load | Set by grade, roll cover and blade material β doctoring cleanly without damaging the roll is the criterion |
| Holder stiffness | The wider the span, the more the straightness matters; otherwise neither crown nor line load can be set |
By grade, roll cover and blade material together, judged by clean doctoring without roll damage. Start low and raise while watching dust and roll marking β do not torque to a nominal figure from memory.
High line load and long change intervals on dryer and calender positions. It is brittle, so no hammering during fitting, and a soft holder will chip it β a chipped ceramic blade costs far more in roll damage than the blade itself.
Check angle and line load first, then holder straightness and air-tube pressure stability. Only after those are ruled out does blade stiffness or clamping method become the suspect.
Usually yes: replace the tube, seals and quick couplings, then pressure-test. If the holder body itself is distorted, it must go out for straightening β no amount of pressure adjustment compensates.
It depends on line load, roll roughness and filler loading. Judge by doctoring quality and roll wear rather than calendar days; after two or three cycles your own ledger gives the real interval.
One blade set per doctor position, plus air tubes, seals and quick couplings. For ceramic, stock the two most frequently changed positions first rather than every position.